Biosafety Cabinet(BSC-01/02IIA2)

Previous 2 / 3 Next

Biosafety Cabinet(BSC-01/02IIA2) Airtech Biosafety Cabinet(BSC-01/02IIA2) Airtech Biosafety Cabinet(BSC-01/02IIA2) Airtech Biosafety Cabinet(BSC-01/02IIA2) Airtech Biosafety Cabinet(BSC-01/02IIA2) Airtech Biosafety Cabinet(BSC-01/02IIA2) Airtech


Description


Friendly Control Panel
  • LED screen, show the air velocity, time, fan station, alarm in real time.

Safe and Reliable, Energy-Efficient
  • DC fan and LED light make the operation power consumption save 30%.
  • Intelligent auto-supply system of imported blower ensures the change of air volume less than 10% when the resistance of filter increases 50% and enhance safety.
  • The alarm system for safe operation height is interlocked with light. At the same time light is Interlocked with sterilizing.
  • Leak detection in cabinet, no leakage at 500Pa.
  • UV light with set timer, safer and high efficiency.


Humanized design

  • 10°sloped front make it comfortable to operator.
  • Negative pressure and double layers chamber around ensure non-leakage, non-pollution. Demountable circular-arc armrest can alleviate working tiredness and make it easy to transport.
  • Front window adopts hanging lifting system (Imported from Japan) and more than 5mm thickness security glass with arbitrary positioning, high stability and convenient to sterilization when it closed.
    (Patent No.: ZL97235425.5)
  • Movable stainless steel worktable 4 liter capacity stainless steel collecting tank with below down valve, easy to collect water, cleaning and disinfection.
  • Non-obstructive air return mode in the front suction channel (Patent No.: ZL200520140353.8).
  • The adjustable leveling foot is without exposure thread.


HEPA filters

  • USA HV HEPA Filter Medium, provide 99.995% typical efficiency for particle size over 0.3 microns, and the materials is glass fiber.
  • A minimum ISO 5 air quality in the work area
  • Patent of non leakage.
  • Every HEPA filters will be tested to ensure non leakage.

Model/Item BSC-1301IIA2 BSC-1302IIA2
Cleanliness HEPA: ISO 5
Filtration Efficiency ≥99.995%, @0.3μm
Downflow Velocity(m/s) 0.35
Inflow Velocity(m/s) 0.54
Noise(dB(A)) ≤67
Vibration(μm) ≤5(center of tabletop)
Power Supply AC115V£¬1φ£¬60Hz AC230V£¬1φ£¬50/60Hz
Opening Height(mm) 250
Operator Protection A. Total colony in impaction sampler ≤10CFU./time B. Total colony in impaction sampler ≤5CFU./time
Product Protection Total colony in culture dish ≤5CFU./time
Cross Contamination Total colony in culture dish ≤2CFU./time
Max Consumption(with spare socket)(kVA) 1.5 /
Rated Power(without spare socket)(kVA) 1 0.46
Weight(Kg) 300
Working Dim.(W*D*H) (mm) 1270*600*620
Overall Dim.(mm) (W*D*H) (mm) 1500*790*2050
Size (W) and Qty. of Light 24.5*¢Ú
Size (W) and Qty. of UV Light 15*¢Ú
Lumin. (Lx) ≥750
Cabinet Materials High-grade steel and lacquered in ivory
Working Area Materials SS304 fully finished
Air Direction Top out
Plug Style USA Type(AC125V/10A) /