Recent Updates

Dian Permata Sdn Bhd added 10 new photos
Oct 30, 2018 at 01:21 pm —
Dian Permata Sdn Bhd added new service in Specialist Services
Oct 30, 2018 at 01:09 pm —

Additional Tests

Local Exhaust ventilation (LEV) inspection, testing and validity by well-trained hygiene technicians and test according to meet the DOSH requirements. Local Exhaust Ventilation (LEV) is an engineering control system used to reduce exposure to airborne contaminants in a workplace by capturing and extracting the contaminant at the source of the emission. As LEV is a control measure under the ˇ°The Control of Substances Hazardous to Health (COSHH) Regulationsˇ± it must be regularly and thoroughly inspected and tested and states that any employer who uses Local Exhaust Ventilation to control hazardous substances, must ensure that it is operating effectively   Stack Emissions Monitoring & Testing Services, Chemical exposure monitoring which comply to DOE standard Stack Emissions monitoring is referred as Stack emission testing or stack emission monitoring. It is a process to measure emission of industrial waste or pollutants emitted into atmosphere. The pollutants emitted from stack can be solid, gaseous, liquid organic or inorganic.   The objective of Chemical Exposure Monitoring is to measure hazardous contaminants suspended in air that is being exposed to employees. The Chemical Exposure monitoring would enable employers to measure the contaminants concentration in air, comparing it against the stipulated limit depicted in the regulations. read more
Dian Permata Sdn Bhd added new service in Toxic Gas Filtration & Save Heaven
Aug 30, 2018 at 03:54 pm —

Toxic Gas Filtration & Save Heaven

In the event of a release of a hazardous contaminant into the atmosphere, either intentional (chemical or biological terrorism) or by industrial accident, there is a need to protect the occupants of the buildings in the immediate area. The sudden and immediate danger requires an emergency gas removal system that has to be operational within a few seconds. Typically, the simplest mechanical technologies not only provide the best result; they also prove to be more reliable. Hopefully, a spill will never occur but if it does you want to be prepared. Our 35 years, Circul Aire has been designing and manufacturing airborne contaminant control system that help to protect against lethal agents dispersed into building air distribution system and provide first line of defense with a single platform concept for outdoor and indoor air contaminant systems. Our system can be found in Airport, office building, emergency muster stations, bunkers, emergency respond centers, embassies and consulates, government building, military and heavy industries. read more
Dian Permata Sdn Bhd added 2 new services in Air Purification
Aug 30, 2018 at 03:14 pm —
Dian Permata Sdn Bhd added 2 new services in Specialist Services
Aug 30, 2018 at 02:44 pm —
Dian Permata Sdn Bhd added new photo in Contained Air Solutions (CAS)
Aug 30, 2018 at 01:57 pm —
Negative Pressure Pharmaceutical Isolator

Negative Pressure Pharmaceutical Isolator

2 or 4 Glove models available Details Negative pressure pharmaceutical isolators are separative devices used for the safe handling of cytotoxic drugs and to retain other process generated particles, the isolator provides a full barrier protection between operator and product. The main work area maintains air quality levels in accordance with Grade 'A' EU GMP (Class 100) this is supplied via a HEPA filter providing unidirectional airflow. All isolators from CAS come complete with interlocked type 'D' transfer hatches. The following features are also available: Body fully manufactured from grade 316 stainless steel Work area base and read panel polished 316 stainless steel Easy to use Blue LCD backlit display showing work area and transfer hatch pressures Audible and Visual alarm with clear and informative display High air change rates in both work area and transfer hatches 2 Glove and 4 Glove models available read more
Dian Permata Sdn Bhd added 3 new photos in Airtech
Aug 30, 2018 at 10:19 am —
Biosafety Cabinet (BSC-04IIB2)
Biosafety Cabinet(BSC-01/02IIA2)
Biosafety Cabinet(BSC-III)
next page

Switch to Mobile Version